- 欢迎光临Satisfactory国区BWIKI。请登录您的B站账号,方可使用页面编辑与评论功能。
管道
阅读
2020-07-17更新
最新编辑:Liwers_Loor
阅读:
更新日期:2020-07-17
最新编辑:Liwers_Loor
Stub | This article is a stub. You can help 幸福工厂WIKI_BWIKI_哔哩哔哩 by expanding it. |
Pipeline | ||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Outside indicators show volume, flow rate and direction. Transports up to 300 m模板:Cubic (300k liters) of fluid per minute. Used to transport fluids. | ||||||||||||||||||||||||||||||||||||||||||||
解锁 | Tier 3 - Coal Power | |||||||||||||||||||||||||||||||||||||||||||
分类 | Logistics | |||||||||||||||||||||||||||||||||||||||||||
二级分类 | Pipelines | |||||||||||||||||||||||||||||||||||||||||||
规模 | ||||||||||||||||||||||||||||||||||||||||||||
宽度 | 2 m | |||||||||||||||||||||||||||||||||||||||||||
长度 | (1~50) m | |||||||||||||||||||||||||||||||||||||||||||
高度 | 2 m | |||||||||||||||||||||||||||||||||||||||||||
name = Pipeline | researchTier = Tier 3 - Coal Power | powerUsage = | powerGenerated = | fuel = | overclockable = | inputs = | outputs = | width = 2 | length = (1~50) | height = 2 | sizeNote =
}} | |||||||||||||||||||||||||||||||||
制作 | ||||||||||||||||||||||||||||||||||||||||||||
制作途径 | Build Gun | |||||||||||||||||||||||||||||||||||||||||||
所需零件 | ||||||||||||||||||||||||||||||||||||||||||||
材料 | ||||||||||||||||||||||||||||||||||||||||||||
模板:ResourceBreakdown
{{#cargo_store:_table = crafting_recipes |
product = Pipeline | recipeName = Pipeline | experimental = | unreleased = | alternateRecipe = 0 | mainRecipe = 1 | researchTier = Tier 3 - Coal Power | craftedIn = Build Gun | inCraftBench = | inWorkShop = | craftingTime = | craftingClicks = | productCount = | productsPerMinute = 0 | product2 = | productCount2 = | productsPerMinute2 = 60 | product3 = | productCount3 = | productsPerMinute3 = 60 | product4 = | productCount4 = | productsPerMinute4 = 60 | quantity1 = 1 | ingredient1 = Copper Sheet | quantity2 = | ingredient2 = | quantity3 = | ingredient3 = | quantity4 = | ingredient4 = | quantity5 = | ingredient5 = | quantity6 = | ingredient6 = | quantity7 = | ingredient7 = | quantity8 = | ingredient8 = | quantity9 = | ingredient9 = | quantity10 = | ingredient10 =
}} |
The Pipeline is used to transport fluids between structures in a similar manner to Conveyor Belts. It can transfer up to 300 m模板:Cubic of fluid per minute. In order to transport fluids vertically, a sufficient amount of pressure has to be reached. A 1 meter climb equals 1 pressure. Pipeline pressure can be increased using a Pipeline Pump.
The volume of each individual Pipeline segment is set by its length.
Fluids
The Pipeline can transport one of the following type of fluids below:
A Pipeline segment can only contain 1 type of fluid at a time.
Build mode
When building a pipeline, different build modes can be cycled by either pressing or holding 模板:Key.
- Default: The default build mode.
- Vertical: The pipe will attempt to stay at the same height as the starting point, then turns vertically when approaching the ending point.
- Conveyor 2D: Similar to default mode but with a much smaller turning radius - useful when building a pipe in other build modes is not possible.
Turning radius
- Pipelines have a minimum turning radius of 2 meters. When building pipelines at 90 degree turns, count 2 meters or 2 'grids' from the turning point.
- Its graphical appearance may display that the radius smaller than 2 meters, but it is still impossible to build a turning point of 1 meter.
Pipeline support
When building from a fixed point to a free point, a Pipeline Support will be automatically added to the 2nd point, including its building cost. The support itself is confirmed in two stages. The first stage confirms the rotation of the support along its vertical axis; this is adjusted with the mouse scroll wheel. The second stage confirms the height and pitch; the former adjusted by looking at the desired height (max. 7 metres) and the latter adjusted via the mouse scroll wheel. Each build stage is confirmed with LMB.
Flow Indicator
The Pipeline is a metal tube. If the pipe contains a straight part of minimum 6 meters, a Flow Indicator will appear in the middle of the segment, which is a set of 3 rings on a retractable rail. A pipeline indicator displays 4 indications:
- Type of fluid content: the color of the window (the middle part that exposed) corresponds to the type and color of the fluid it is carrying.
- % Amount of fluid: the distance of the 1st and 3rd rings from the center ring corresponds to the % amount fluid. If the pipes is full, then the rings are fully retracted. If pipe is empty, all the rings collapse at the middle.
- Flow direction: Indicated by the pattern of the pulses. The first ring that expands indicates the fluid is flowing from that direction. The fluid flows towards the 3rd ring.
- Flow rate: By the distance of the ring expansion. If the flow rate is very small, the rings barely 'breathe'.
The pulse rate is always maintained at 1 pulse per second.
Flushing
The Pipeline contents can be emptied by interacting with a segment of it (default 模板:Key) and then turning the flush lever in its UI.
There are 2 options:
- If 'Pipe Segment' is chosen, only that segment is flushed.
- If 'Entire Pipe Network' is chosen, all pipes connected to the selected pipe are flushed.
Head lift
Buildings with fluid outputs (e.g. Refineries, Water Extractors, or Oil Extractors) output with recommended head lift of 10, which corresponds to a 10m high rise of the fluid. Pipeline Pumps output with recommended head lift of 20, which therefore corresponds to a 20m high rise of the fluid. Buildings can still push fluid about 2 meters beyond the recommended head lift with reduced flow.
Even though mechanical produced pressure doesn't add up, gravitational pressure does. For example, if your fluid producer would be located 50m above your base ground level, it could rise (from the base ground level's perspective) 60m without the use of any additional pump (10 pressure of the fluid producer + 50 "pressure" from gravity).
- Gravity in Pipelines 1.png
- Gravity in Pipelines 2.png
- Gravity in Pipelines 3.png
- Ficsit Pipeline Infograph 3.png
A collection of sample Pipeline builds, including Overflow, Input Manifold and Line Balancer.
This effect arises from the fact that the liquid fills the tube almost as in reality, first the lowest parts, then the highest. If there is a difference in height, the rising pipe must first fill up before the liquid can be transported further.
In part the same is true for the Industrial Fluid Buffer. As it is filling up, the fluid inside of it rises. Meaning, if you want to completely fill them, the head lift must be at least the height of the buffer.
Overflow valve
There is currently no distinct building in game that allows for controlled overflow of fluids in a pipeline. However there is a workaround by building the following:
- The higher priority fluid consumers should be directly connected to the fluid source with pipe.
- The lower priority fluid consumers should be connected, in series, at the end of the line, with a 10 meter high pipes in-between to restrict the flow. Therefore, when the preceding pipeline is full, the fluid will pass through the restriction.
- Liquid overflow schematic.png
Using head lift and distancing to prioritize the Fuel generators over packaged fuel.
- Pipeline overflow with head lift.png
Stacking 5 Stackable Pipeline Supports to introduce a head lift of 10 meters high to restrict the fluid flow. Only when the pipe before it is full, the fluid can pass through it.
These work based on the following principles:
- Pipes nearer to the fluid source (such as Extractors, Refineries) will be filled first - therefore buildings connected to such pipes will be prioritised.
- Pipes will obey the laws of gravity - pipes at a lower height will fill up before pipes at a taller height.
- Pipes well beyond the generated headlift will never fill up.
Pipe modification and fluid content
- When a Pipeline is modified by either inserting a Pipeline Junction Cross or a Pipeline Pump onto it, all its fluid contents is emptied.
- Similar to above, when a Pipeline Junction Cross or a Pipeline Pump is removed from a previously continuous pipe, all its fluid contents is emptied.
Trivia
- Pipelines were memed by the community since the start of the game.
- Pipelines do not encroach on built foundations, but foundations will encroach upon built pipelines. Thus, always build foundations first, then the pipeline.
Gallery
- Screenshot 2020-02-12 at 12.38.12 PM.png
Pipelines, as seen in the 0.3 Experimental Update Trailer
- Pipeline Water content.png
The UI of a Pipeline, displaying its content and flow rate.
History
- Patch 0.3: Introduced
|